SKX-6000E + series Defibrillator Signal Simulator AED Simulator for daily maintenance and detection. This optimum product is developed by Xuzhou Mingsheng Company for measuring the detection of defibrillator.
SKX-6000E can detect the released energy value of defibrillation/AED, the detection range is 50J-200J.
Features of SKX-6000E are as follows:
Built-in 18650 large-capacity lithium battery, power management module to ensure stable power supply and low interference during use
Output. Optional standard micro USB universal interface power charger.
2. Using menu-style operation, parameter changes are simple, convenient and fast, and convenient for users to set.
3. OLED display is used to display the contents of the menu.
4. Simple button operation, menu management, easy to use.
5. Built-in Chinese and English waveform setting instructions, easy to understand waveform settings and parameter selection.
There are 18 menu items in this simulator, namely:
Serial number | Menu Item | Introduction |
1、 | Waveform selection | Select abnormal waveforms that can be used for simulation |
2、 | Waveform gain | Select the amplitude of the waveform emitted by the simulator |
3、 | Nor cycle | The duration of the normal waveform, in seconds |
4、 | Pvc time | The duration of the abnormal waveform, in seconds |
5、 | Wave type | Select the type of waveform when not automatically switching |
6、 | Automatic conversion | Whether the normal waveform and abnormal waveform are automatically converted |
7、 | Number of triggers | The number of received energy released by the defibrillator can be automatically converted to normal waveform after reaching this value |
8、 | Trigger threshold | Set the energy threshold of the defibrillator. Only after this value can it be converted to a normal waveform |
9、 | language selection | Language displayed by the software |
10、 | Automatic shut-down | Set the time for automatic shutdown |
11、 | Show help | Whether to show boot help |
12、 | Dimming | Adjust the display brightness of the OLED screen |
13、 | manufacturer | Xuzhou Mingsheng Company Logo |
14、 | Detection energy | Whether to allow the switch to detect and display defibrillation energy |
15、 | School zero | Perform zero calibration before the instrument detects energy, and the default has been calibrated before leaving the factory |
16、 | Save Settings | After changing the parameter value, please save the setting and it will take effect next time you turn it on |
17、 | Factory setting | Restore factory default settings |
18、 | version number | Software version number |